Deprecated: Function _get_path_to_translation is deprecated since version 6.1.0! Use WP_Textdomain_Registry instead. in /home/u203735599/domains/softmor.com/public_html/intercovamex/wp-includes/functions.php on line 5383

Deprecated: Function _get_path_to_translation_from_lang_dir is deprecated since version 6.1.0! Use WP_Textdomain_Registry instead. in /home/u203735599/domains/softmor.com/public_html/intercovamex/wp-includes/functions.php on line 5383

Deprecated: ¡La función _get_path_to_translation ha quedado obsoleta desde la versión 6.1.0! Usa WP_Textdomain_Registry en su lugar. in /home/u203735599/domains/softmor.com/public_html/intercovamex/wp-includes/functions.php on line 5383

Deprecated: ¡La función _get_path_to_translation_from_lang_dir ha quedado obsoleta desde la versión 6.1.0! Usa WP_Textdomain_Registry en su lugar. in /home/u203735599/domains/softmor.com/public_html/intercovamex/wp-includes/functions.php on line 5383

Authorized Distributors in USA and Latin America

D8 ADVANCE

The D8 ADVANCE is a real quick-change artist that can be configured to take on a single analytical task with great focus and dedicated components, or a fully featured, multi-purpose solution that is capable of dealing with very diverse analytical needs with highest competence.

Our famous DAVINCI design ensures for all those solutions easy (re)configuration and extensibility to exactly satisfy your analytical needs, now and in the future.

Dynamic Beam Optimization (DBO) provides best in class powder diffraction data by setting new benchmarks in terms of counting statistics and peak-to-background ratio, all without the need for manual instrument reconfiguration.

The high-speed energy-dispersive LYNXEYE XE-T detector uniquely combines fast data collection with unprecedented filtering of fluorescence and Kβ radiation. Its proprietary Variable Active Detector Window and the Motorized Anti-Scatter Screen (MASS) enable data collection from lowest 2Th angles without parasitic low-angle background scattering, in particular air scattering. The fully automated MASS retraction avoids beam cropping, even in combination with continuously variable slits that provide superb counting statistics over the whole angular range.

  • Superb counting statistics allows for faster data collection and increased sample throughput
  • No parasitic low-angle background scattering massively improves data quality of pharma, clay, zeolite and other samples having a large unit cell
  • Best peak-to-background enhances sensitivity for minor phases
  • Full quantification of crystalline and amorphous phases with DIFFRAC.TOPAS

    The DAVINCI design is the D8 ADVANCE’s landmark as a uniquely modular system. From the X-ray tube, through optics and sample stages all the way to the detectors, any user – even a novice – is capable of changing from one beam geometry to another or exchanging individual components with no trouble at all. Therefore, our D8 ADVANCE offers unparalleled adaptability to any conceivable application in X-ray diffraction.

BrochureContact Us